PC-600 is an acid copper plating additive system that has been specifically optimized for use with pulse periodic reverse rectification on a continual production basis.
READ ENTIRE TECHNICAL DATA SHEET BEFORE USING THIS PRODUCT
FEATURES & BENEFITS
The process produces a fine-grained, ductile deposit with excellent distribution characteristics, and is maintained with two components. The combination of PC-600 and a periodic reverse pulse plating rectifier can significantly shorten plating times while maintaining excellent distribution ratios.
PHYSICAL PROPERTIES
Nominal Deposit Characteristics |
|
Electrical Resistivity | 1.68 micro-ohm-cm |
Elongation* | Greater than 18% |
Internal Stress | 750 to 1500 psi |
Density | 9 g/cc |
Ultimate Tensile Strength* | Greater than 36,000 psi |
Solderability | Excellent |
Microscopic Structure | Fine Grained Equiaxed |
*Testing per IPC-TM-650, Method 2.4.18.1 |
PROCESS COMPONENTS REQUIRED
Product Name Product Code
PC-600 Carrier PC-600 Replenisher
EQUIPMENT
Tanks, pipes, fittings and valves should be acid resistant. All plastic parts should be of Teflon?, PVC, PVDF, polypropylene or high-density polyethylene construction. Soft PVC (e.g. Tygon?) is not recommended for constant contact with the bath.
Anode bars, cathode bars and bus bars should be made of copper. Bolts, fixtures, etc. that are not immersed in the plating solution may be made of copper, bronze, 316 stainless steel or titanium. Metal parts that will be immersed in the plating bath should be constructed of titanium.
Acid copper sulfate solutions are corrosive. It is important to protect the floors, plumbing and any other equipment, which may come in contact with the plating solution. Vinyl coatings, asphalt or several coats of rubber-based paint will usually provide adequate protection.
Rectifier output (amperage) should be calibrated to 土5% or less across the working range. Also the pulse wave form (especially the % overshoot and rise time) should be checked with an oscilloscope by a qualified technician.
The preferred rack materials are copper and copper alloys. The rack area, if immersed in plating solution, should be coated with a non-conductive material (e.g. Plastisol?, Koroseal?).
MAKE UP PROCEDURE
Solution |
|
Copper Sulfate Pentahydrate | 65 g/L** |
Sulfuric Acid | 12.7% by volume (230 g/L H2SO4) |
PC-600 Carrier | 3% by volume |
PC-600 Replenisher | 0.20% by volume |
Deionized Water | Balance |
Chloride | 70 ppm |
Note: COPPER SULFATE CONCENTRATE from MacDermid Enthone typically contains about 270 g/L (36 oz/gal) of copper sulfate pentahydrate, or 68.7 g/l (17.5 oz/gal) of copper metal.
Mixing Instructions:
Fill to half of final working volume with deionized water.
With mixing, add the required amount of copper sulfate and dissolve.
With heavy mixing, slowly add the required amount of sulfuric acid. The addition of sulfuric acid produces a considerable amount of heat. If PVC structures are present, monitor the temperature of the solution and do not allow it to exceed 49 °C (120 °F).
Cool, with mixing, to 29 °C (85 °F).
Add 0.41 g/L of Manganese Sulfate monohydrate pre-dissolved in DI water (CAS #10034-96-5, tech grade or better).
With mixing, add the required amounts of PC-600 Carrier and PC-600 Replenisher.
Fill to final volume with deionized water and mix.
Check the chloride content of the bath and add sufficient hydrochloric acid to raise the chloride to approximately 80 ppm.
Note:
(ppm chloride add desired) (bath volume in liters) = mLs of 37% (concentrated HCI to add
425
Electrolyze (dummy plate) the bath for 3 hours at 20 ASF (2 ASD) while maintaining the brightener concentration by CVS, CPVS or dilution Hull cell (the feed rate of PC-600 Replenisher should be about 0.2 to 0.5 mL/amp. hr, however, the initial feed rate for the first day may be higher). The PC-600 Carrier feed rate should be about 0.2 to 0.5 mL/amp. hr. The pulse waveform should be set at 40 msec forward; 2.3 msec reverse and a 2 to 1 reverse current ratio. Plate a test panel and obtain cross-section results to be sure the optimum performance is obtained before starting production. Some plating tank or board designs may require special waveforms or brightener concentrations in order to obtain optimum results.
OPERATING CONDITIONS
The operating conditions for the PC-600 Acid Copper process are as follows:
Parameter | Range | Target |
Copper Sulfate | 55 to 75 g/L 7.3 to 10 oz/gal | 65 g/L 8.6 oz/gal |
Sulfuric Acid | 215 to 245 g/L 12 to 13.5% by volume | 230 g/L 12.75% by volume |
Chloride | 50 to 90 ppm | 70 ppm |
PC-600 Carrier | 1 to 5% by volume | 3% by volume |
PC-600 Replenisher | 0.05% to 0.35% by volume | 0.20% by volume |
Temperature | 21 to 27 °C 70 to 80 °F | 24 °C 75 °F |
Forward Cathode Current Density | 8 to 25 ASF 0.86 to 2.7 ASD | 17 ASF 1.8 ASD |
Pulse cycle | Forward Time: 40 milliseconds Reverse Time: 2.3 milliseconds Reverse CD Ratio: 2 to 1 (Pulse cycle can vary depending on plating operation.) | |
Agitation | Air or eductors (eductors preferred) and cathode rod | |
Filtration | Continuous, 2 to 3 turnovers per hr (1 micron polypropylene filter is recommended.) | |
Anodes | Phosphorized copper (0.03 to 0.08% phosphorous). | |
Anode Baskets | Titanium (square baskets with nuggets is recommended). | |
Anode Hooks | Titanium | |
Anode bags | Polypropylene (cotton and other cellulose based materials are unacceptable) |